Change the value of the parameter ENC_abs_source. 7 0 obj The configuration was only partially transferred to the drive and might be inconsistent now. Parameter write not permissible (READ only). System inertia changes during operation. Verify the function and wiring of the reference switch. Encoder or encoder cable inoperative. The signal input function does not support the selected debounce time. Change the system inertia used for velocity observer calculations via the parameter CTRL_SpdObsInert. VFD ERROR CODES Some VFD issues can be resolved before requesting service. Now, you will be the first to know the updates from Schneider Electric. Index pulse signal not connected or not working properly. Access occupied by another channel (for example: Commissioning software is active and fieldbus access was tried at the same time). Autotuning: Test movement could not be started, Autotuning: Power stage cannot be enabled. Use correct password. Reach out to our customer care team to receive more information, technical support, assistance with complaints and more. Absolute position for encoder 2 cannot be set. Internal timeout in communication with fieldbus module. The safety function STO was activated in the operating state Operation Enabled. Internal nonvolatile memory not operative. eSM module: Safely Limited Speed (SLS) exceeded in machine operating mode Automatic Mode. eSM module: Error detected during Safe Operating Stop (SOS). Reach out to our customer care team to receive more information, technical support, assistance with complaints and more. Encoder error or error in internal communication with the drive detected (for example, EMC). You will receive your welcome message soon. System error detected: Internal software error, System error detected: System stack overflow, System error detected: Division by zero (internal), System error detected: Overflow during 32 bit calculation (internal), System error detected: Size of data interface does not match, Parameter outside of value range (calculation error detected), System error detected: Internal range exceeded, System error detected: Calculated value cannot be represented as a 32 bit value, System error detected: 24 VDC below undervoltage threshold for shutdown, System error detected: Internal timer basis missing (Timer0), System error detected: Memory area locked, System error detected: Calculated value cannot be represented as a 16 bit value, System error detected: Impermissible function call from interrupt service routine. PacDrive Diagnostic Messages . Position evaluation error detected (AB encoder signals), Checksum error detected in EnDat encoder data. Verify that the system can easily be moved. System error detected: Error in motor encoder communication. Position of motion blend has already been passed. The cycle time tolerance may not exceed one quarter of the set cycle time. Motor overload fault (OLF) is triggered by the motor pulling current above the ItH (Motor Them Current) that is programmed into the drive. The positive limit switch was activated because movement range was exceeded, incorrect operation of limit switch or signal disturbance. Recalculation must be started within 30 seconds after initialization. The hardware revision does not support the function. Title: Toshiba E3 ASD Landis and Staefa FLN Interface Manual.pdf Author: Tanya Keywords: TRIAL MODE / Expert features: Print encrypted PDF documents o 8008 Controller logout. Configuration error detected: Invalid BISS encoder parameter setting. Capture input 1 has not been set to both edges (IDN169). The values for the speed limits for multiple SLS are not in ascending order. I'd like to receive news and commercial info from Schneider Electric and its affiliates via electronic communication means such as email, and I agree to the collection of information on the opening and clicks on these emails (using invisible pixels in the images), to measure performance of our communications and improve them. Parameter cannot be written in this eSM state. The activation of a new operating mode is not possible, the error code is sent as the response to the activation command. Discover our Q1 revenues on April 27, at 7.30 am CET.Conference call at 8.30 am CET. The time between the initialization of the recalculation and the start of the recalculation has been exceeded (30 seconds). Negative limit switch triggered with positive direction of movement. x}rd#_QxQJa#vZ?PMfq}3 2q!gT=D$lFpozs}?^IEetB||)W.8e|_4Y kMm^V~jj0o;;*lN:G9qp1{ ybPICQODe4QikLms8?~,L hXx+k3jsmP']av'nrNamw Welcome to the Schneider Electric corporate Website, Access mySchneider, your personalized digital experience. Error detected during parameter switching. Please enter a valid email address, Problem with captcha verification, please check your connection. Verify encoder cable: wiring and shield connection.. Verify encoder parameter settings. Incorrect sequence of steps for scaling (fieldbus). NVE41289.03 www.schneider-electric.com Altivar Machine ATV320 NVE41289 01/2017 Altivar Machine ATV320 Variable Speed Drives for Asynchronous and Synchronous Motors Installation Manual If monitoring functions of the drive detect an error, the drive generates an error message. Overload of transistor for braking resistor. The Quick Stop option code has been set to -1 or -2 which causes the drive to transition to the operating state 9 Fault instead of the operating state 7 Quick Stop Active. Gain actionable insights on installed equipment health to maximize uptime and boost performance. DC bus undervoltage (Quick Stop threshold), Undervoltage DC bus, missing mains supply, undervoltage mains supply or overvoltage mains supply. Please enter a valid email address, Problem with captcha verification, please check your connection. Restart the drive. Fieldbus module: Active IOC physical layer does not match the IOC physical layer of the detected fieldbus module. Original state of a parameter cannot be restored after an error was detected during recalculation of parameters with user-defined units. The levels of the inputs STO_A and STO_B were different for more than 1 second. The movement range limits were exceeded and the zero point is no longer valid. Set drive to operating state Operation Enabled and repeat the command. The motor is blocked so that more current is used than under normal conditions. If issue persists, then there could be an issue with the RJ45 cable, or MODBUS Router. Fieldbus module has been removed or fieldbus module is inoperative. Search for a solution on your own, or connect with one of our experts. Drive Profile Lexium: Write request with incorrect data type. An external tool has tried to transfer the configuration without locking the drive. The encoder does not support motor temperature monitoring. Function not available in this type of device. Code W P 078 e 700C Diag. Download at www.schneider-electric.us/go/drives VW3A8114 Catalog number VW3A21212 Catalog number VW3A31852 SoMoveMobile Software VW3A21212 Altivar 212 Drive Technical Characteristics Environmental Specifications Temperature ratings Altitude ratings Humidity Vibration resistance Shock resistance Pollution degree Verify encoder adjustment. Medium Voltage Distribution and Grid Automation, Product Documentation and Software Downloads, Panelboards / Switchboards and Switchgear, Controllers, Expansion Modules, Servers & HMIs, Power Metering and Energy Monitoring Systems, Power Quality and Power Factor Correction, Integrated Power and Control Solutions (IPaCS) Equipment, Low Voltage/Medium Voltage Prefab Substations, Pushbuttons, Switches, Pilot Lights, Control Stations and Joysticks, Data Center Security and Environmental Monitoring. Search topic-related frequently asked questions to find answers you need. Incorrect signal evaluation in drive. Error detected at signal input for reference value. Change the cycle time in the master controller to a cycle time supported by the drive or verify synchronization requirements. Reference switch inoperative or not correctly connected. Drive Profile Lexium: On activation of the profile, no dmControl, refA or refB has been mapped. Fieldbus module not correctly mounted in the slot. Connection monitoring has detected an interruption of the connection. 28K views 4 years ago How to Altivar Machine ATV320 | Schneider Electric Tutorial for troubleshooting an EPF1 Fault (External Fault) on the Altivar ATV320 Variable Frequency Drive (VFD).. The negative limit switch was activated because movement range was exceeded, incorrect operation of limit switch or signal disturbance. All rights reserved. Parameter AT_gain or AT_J are written during Autotuning. Change the velocity observer dynamics via the parameter CTRL_SpdObsDyn. System error detected: Position initialization not possible. Wire break or connected devices are inoperable. Recalculation for scaling is already running. % Value in additional error information shows the Modbus register address of the parameter where the initialization error was detected. Incorrect values in parameter ENCDigSSIResSgl or ENCDigSSIResMult. Autotuning: HALT request has stopped the autotuning process, System error detected: FIFO memory overflow, Motor has been changed (different type of motor). Resolver: Signal communication subject to interference, System error detected: Encoder module RES is not ready for position evaluation. Verify that the configuration file is valid and matches the type and version of the drive. D4: Sine/cosine inputs exceed DOS mismatch threshold. There is no encoder available at the input specified via the parameter ENC_abs_source. Welcome the the Schneider Electric French website. An external tool has downloaded a configuration which has an incorrect format. Verify that you really want the selected scaling factor. Amplitude of encoder analog signals too low. Not possible to configure difference value capturing. Indeterminable type of fieldbus module detected in fieldbus slot. Index pulse is not available for the encoder, Error in analog signals from encoder detected (additional info=Internal_DeltaQuep), System error detected: Indeterminable type of encoder, Configuration error detected: Encoder module and selected machine encoder type do not match, Configuration error detected: Encoder module and selected motor encoder type do not match, Configuration error detected: Encoder module parameterized, but no module detected, Configuration error detected: No motor encoder type selected for encoder module, Configuration error detected: No machine encoder type selected for encoder module. Keep motor from moving while Safe Operating Stop is active (external forces, loads). Cyclic communication: Synchronization signal missing. The drive does not support the configured cycle time or the difference between the measured cycle time and the configured cycle time is too great. Verify index pulse signal and connection. Parameter only accessible at expert level. Two cycles have passed without a synchronization signal having been received. In this case, operation with velocity observer is not possible and the velocity observer must be deactivated. RS485/Modbus: Incorrect number of monitor objects. Verify the speed limits for machine operating modes Automatic Mode and Setup Mode and change them as required. A data set of the operating mode Motion Sequence could not be recalculated. Reference movement to index pulse cannot be reproduced. )/)1xR\!ThBV|m@ eSM module: System error detected: Position evaluation error detected (values not identical). AL508. The recalculation has been started prior to the initialization. Enable limit switch via 'IOsigLimP'or 'IOsigLimN'. There must be a minimum motor movement at least once every 36 hours. Logical protocol error detected: Incorrect length or unsupported subfunction. Bridging progress and sustainability for all. Command needs a valid zero point (ref_ok=1). Drive not in operating state Operation Enabled. Calculated offsets for current sensors out of range. Close other access channel (for example, other instance of commissioning software). Configured debounce time not possible for this signal input function. Setting the offset position is not possible. Not possible to initialize recalculation for scaling. The movement exceeded the adjusted movement range during Autotuning. Activation of a new operating mode is not possible while another operating mode is still active. The multiturn resolution of the machine encoder with reference to the motor shaft exceeds the system limits, for example, due to the mechanical gear ratio between machine encoder and motor encoder. Set a speed limit not equal to zero for multiple SLS. eSM module: System error detected: ESM5VDC undervoltage, eSM module: System error detected: 5V overvoltage, eSM module: System error detected: 5V undervoltage, eSM module: ESMSTART: Maximum permissible pulse duration exceeded. If you use the internal braking resistor, contact your Schneider Electric service representative. A parameter modification requires the drive to be powered off and on. Start your sales inquiry online and an expert will connect with you. eSM module: /ESTOP signal for EMERGENCY STOP triggered. Verify that the device is on. E 1504 2 Error detected in operating mode Motion Sequence (additional info = detailed error code). Increase delay for eSM control of Safely Limited Speed (SLS) or decrease eSM deceleration ramp for reaching Safely Limited Speed (SLS). ?`wy:Zvv;c@8\t8n }DI-Ql'AD361)-BN> [7md$QQ)o0>Z9XOW; fa$f~8UI Perform a Fault Reset. Verify that the parameter configuration is valid before starting the recalculation procedure. You will receive your welcome message soon. Resolver: Loss of signal, position unreliable. eSM module: Safely Limited Speed (SLS) exceeded in machine operating mode Setup Mode. Please enter a valid email address Frequency of reference value signal is too high. Undervoltage in internal eSM power supply. Parameter cannot be changed because the external braking resistor is active. Power the drive off/on and retry to download the configuration or restore the factory settings. eSM module: System error detected: Boot program: Invalid address. Code 8503 / external diag. Contact your Schneider Electric service representative. Position difference during the wake and shake procedure is too high. Maximum position deviation between motor encoder and machine encoder exceeded. Power stage cannot be enabled in the operating state Not Ready To Switch On. eSM module: System error detected: Indeterminable state of eSM state machine. This may have been caused by an external load. Absolute position is different from incremental position, Amplitude of analog signals too high, limit of AD conversion exceeded. The velocity was set to a value greater than the maximum permissible velocity in parameter CTRL_v_max or M_n_max, whichever is lower. Voltage at the ESM24VDC connector to low. Use a differently sized motor that can withstand the load torque. The scaling factors for position, velocity or acceleration/deceleration are beyond internal calculation limits. This may not work because another tool had already locked the configuration of the drive or the drive is in an operating state that does not allow locking. inside the Drive we also have internal fault code for safety but with only access by communication (for version up to V1.5ie08) . The last saving procedure may not have been successful; the memory card may be inoperative. Contact your Schneider Electric service representative. D6: Sine/cosine inputs below LOS threshold. If the quasi absolute function is active, only power down the drive if the motor is at a standstill and do not move the motor shaft when the drive is off. Discover EcoStruxure Asset Advisor, a suite of cyber-secure, cloud based digital services for monitoring asset health and reducing downtime. Verify release of direction. Command is being processed or communication may be disturbed (EMC). The velocity has been set to a value greater than the maximum possible velocity (the maximum velocity is 13200RPM). Contact your Schneider Electric service representative. In the case of overtemperature, use a motor with a higher winding voltage or use a drive with a lower nominal supply voltage. Parameter of CPU_A is not identical to parameter of CPU_B. The movement exceeds the parameterized maximum movement range. eSM Disable requires the safety module eSM to be in operating state Operation Enabled. Motor not properly mounted (thermal isolation). This applies to the following series: Altivar ATV12, ATV312, ATV32, ATV61, ATV71. No encoder connected or encoder does not support setting of absolute positions. Parameter changed that requires a restart of the drive. Manual tuning/Autotuning: Movement out of range. o 8007 Controller login. eSM is in state Quick Stop Active or Fault Reaction Active or Fault. 2019 Schneider Electric. Command not permissible while the power stage is enabled (operating state Operation Enabled or Quick Stop Active). Error detected during parameter check (for example, reference velocity value for operating mode Profile Position is greater than maximum permissible velocity of drive). The following message is displayed on Alarm overview display when the alarms or warnings are issued by the drive units. Verify wiring of ESMSTART. Verify that you have the correct device type, in particular type of motor, type of encoder, holding brake. Schneider alt fault code | schneider altivar fault code manual | Diagnostics and troubleshooting HABSHI TECH 29.5K subscribers Subscribe 18K views 4 years ago KOLKATA Manual code of. Verify the position of the motion blend and the movement range. The manufacturer data has been stored with a physical layer different from the physical layer normally used by the module. Request to a module is blocked because the module is currently processing another request. An error was detected during the recalculation. Autotuning has been started twice simultaneously or an Autotuning parameter is modified during Autotuning (parameter AT_dis and AT_dir). Verify setting of parameter WakeAndShakeGain. Not possible to load parameters into safety module eSM. Terminate the active operating mode or disable the power stage. The operating state at the beginning of the commutation offset identification must be Ready To Switch On. File cannot be uploaded: Incorrect file ID, Data stored after a power outage is invalid, System error detected: No bootloader available, Configuration error detected (additional info=Modbus register address). System error detected: Motor encoder inoperative, System error detected: Length specification for user data too great, System error detected: Communication with encoder not possible, Motor without electronic motor nameplate (for example, SER motor), No data segment of the electronic motor nameplate, System error detected: Motor configuration cannot be written, Not possible to write motor configuration, Incorrect encoder type selected with parameter MotEnctype, Error detected during the internal conversion of the motor configuration, Parameter of the motor configuration out of permissible range. Basic configuration of drive required after factory setting. System error detected: Calibration analog/digital converter during manufacturing / incorrect BLE file, System error detected: Invalid encoder parameter. Cyclic communication: Incorrect synchronization. Privacy Policy. Internal communication with fieldbus module not correct. Only displayed by the commissioning software. RS485/Modbus: Interruption of the connection. Code W P0623 e 7007 Diag. Below are some of the most common fault codes for the Schneider Altivar VFD/VSD Drives: Common cause is loss of power, power cycle the unit. System error detected: Invalid internal selection. Verify permissible movement range value and time interval. Assign the function Relative Movement After Capture to a digital input. Analog encoder signals are subject to interference. eSM module: Output /INTERLOCK_OUT (cross fault to another output detected), eSM module: Output RELAY_OUT_A (cross fault to another output detected), eSM module: Output CCM24V_OUT_A (cross fault to another output detected), eSM module: Output AUXOUT1 (cross fault to 24 V detected). More than one signal positive limit switch/negative limit switch/reference switch active. If the detected error persists, contact your Schneider Electric service representative. The movement has passed beyond the position of the motion blend. Install latest commissioning software version. The winding voltage of the motor is lower than the nominal supply voltage of the drive. The motor was not mounted properly, for example, it is thermally isolated. 0:00 / 1:56 How to reset SLF Serial Link Fault on ATV312 | Schneider Electric Support Schneider Electric 175K subscribers Subscribe 167 58K views 7 years ago Step by step process for. Verify all connections and cables used for data exchange. Welcome the the Schneider Electric French website. ATV32 Safety evolution V1.5ie08 Correction on SAFF fault due to interruption of internal communication V1.8ie11 Add SLS Type 4 function Add new parameter (STFR filtered) to be able to check safety speed. I'd like to receive news and commercial info from Schneider Electric and its affiliates via electronic communication means such as email, and I agree to the collection of information on the opening and clicks on these emails (using invisible pixels in the images), to measure performance of our communications and improve them. Error response can be adjusted via parameter ErrorResp_p_dif. The parameters have been reset to the default values. A previous file transfer has been aborted. This condition may have been caused by the encoder. Activation of a function which is not available in the active operating mode. Medium Voltage Distribution and Grid Automation, Power Quality and Power Factor Correction, Controllers, Expansion Modules, Servers & HMIs, Push Buttons, Switches, Emergency Stops and Pilot Lights, Power Supplies, Power Protection and Transformers. Drive overload (foldback) The foldback current of the drive has dropped below the value specified via the parameter P1-23. Speed limit for machine operating mode Setup Mode must not be greater than speed limit for machine operating mode Automatic Mode. Now, you will be the first to know the updates from Schneider Electric. Motor short circuit and disabling of the power stage. Resolver signals are subject to interference. The memory card has been write-protected. Verify resolver cable: wiring and shield connection. Start a movement before the motion blend is activated. Use a different position scaling factor or deactivate the selected function. The parameter ErrorResp_PDiffEncM is set to "Error Class 1" or "Error Class 2". or terminate active operating mode with HALT command. Invalid write access of bootloader to flash memory range. The following information is available for each error message: The table below summarizes the error codes classified by range. The specific type of device does not support this kind of file. Verify connection of STO_A and STO_B. Modify the parameter AT_n_ref or AT_n_tolerance to meet the required condition. Verify the gear ratio in the operating mode Electronic Gear. Attention: these dimensions concern fixing holes. Target position overtraveled with function Relative Movement After Capture. Verify correct connection and function of limit switch. Increase the movement range value or disable movement range monitoring by setting AT_DIS = 0. Wait for complete stop before removing HALT signal. Select another function or change the operating mode. Incorrect I/O data configuration (additional info = Modbus register address). Schneider Electric - CCC Expert VSD - A.Dufoss - 16/10/2014 1. eSM module: Input ESMSTART high instead of low (manual start). Processing only possible with linear ramp. eSM module: System error detected: States of eSM state machines not identical, eSM module: Output AUXOUT1 (cross fault to another output detected). Overflow during calculation of acceleration. Position overflow, zero point is therefore no longer valid (ref_ok=0). Encoder without temperature sensor, incorrect encoder connection. These limit switches are not assigned to inputs. Learn more and find impacted catalog numbers. eSM module: System error detected: Velocity evaluation error detected (values not identical). The password that was sent by the configuration tool is not identical to the password stored in the device. During a configuration download, one or more configuration values were not accepted by the drive. Tutorial for troubleshooting the INF6 fault (internal option fault) on the Altivar ATV61 and ATV71 Variable Frequency Drives (VFD) typically caused by a loose option card or two serial cards.

How To Talk Dirty To A Capricorn Man, Skyrim Learn All Enchantments Command, Pendleton Fabric For Upholstery, Food Waste Statistics 2021 America, Articles S