Jumped in and noticed it dropped to 99. We called the gas company, they installed a larger meter (for free), and the problem never recurred. Seemed to fire up normally, whoosh and heat blowing etc. If you have an account, sign in now to post with your account. I assume they were living in there this past winter. You need to figure out which of these possible things are wrong with the blower. When the burners ignite, raise the thermostat and examine the reading. Once I installed a local regulator, it worked the first time. If voltage appears and the fan doesn't start, it's the motor. Look at the glass eyeball to see if you see the igniter glowing. Just wanted to pass on about this piece of crap. If not, use steel wool orsandpaper to clean.Make sure that the spark rod and flame sense rod are positioned properly, per theMidco Manual, page 9, Figure 8.Make sure that the ceramic insulators for the spark rod and flame sense rod are notcracked, chipped or broken.Make sure that the ignition spark is occurring at the tip of the spark rod.Make sure that the wires and connections for the spark rod and the flame sense rodare tight and proper.Make sure that the burner is properly earth grounded.Make sure that the burner is set up properly, see manual, page 7, Table 3.Make sure that the gas valve is working properly and that gas is flowing to the burnerhead.Make sure that the air shutter setting is proper by using a combustion gas analyzer.The minimum flame sense signal strength is 0.7 DC microamps. Anyway after I put it back in after checking it, I did tighten the nuts carefully (not so tight as to crack the ignitor base) and still the until did not fire. Im assuming you don't turn off power or disconnect the bonding? However, tonight, it had one. Our Jandy pro series jxi heater says check flow valve and Our Jandy pro series jxi heater says check flow valve and isnt heating.it was installed 1 month ago read more Poolservice123 Owner Associate Degree 1,028 satisfied customers When I turn pool heater on in shows int he display Fuselink my 16 year old lt just started displaying the AGS error. I have a Jandy JXI400 heater. The pressure switch prevents the burner from operating if the pool water pump fails or the water filter becomes clogged. Our installer could not find anything wrong with the unit, so he surmised it was caused by insufficient gas pressure. Once done trying to turn on the heat threw FAULT-CHECK IGN CONTROL. I can't speak for is this is a common issue or not as I haven't seen or heard of such. I missed the blower not starting. Stupid question: Doesn't the blower fire up and purge the system BEFORE the igniter is triggered? Water temp is about 58. Now this happens now and then since I bought the unit. I keep reading the intake is on the bottom of the heater, but then there's this air pressure slider on the side which is adjustable. Boasting an 84% thermal efficiency rating and a low-NOx design, the JXi is available in both natural and propane gas models. This corrected a "Check IGN" message about a year after installation and I never had a repeat. Jandy Pro Series Gas-Fired Pool and Spa Heater, Pro Series JXi Gas-Fired Pool and Spa Heater, Jandy JXi 400 Installation And Operation Manual (48 pages), Indoor and Outdoor Shelter Exhaust Conversion, Indoor and Outdoor Shelter Exhaust Termination, Inspection and Replacement of Existing Vent System with New Components, Connect the Digital Differential Manometer, Pump Sizing for Replacement in an Existing Pool, Install Pressure Relief Valve Kit # R0336101, Auxiliary Components, Chlorinators, Ozone Generators, and Sanitizing Chemicals, Connecting to a Remote Pool-Off-Spa Selector (3-Wire Connection), Connecting to an Aqualink Control System or Remote TSTAT (2-Wire Connection), To Restore Heater Control Panel Functionality after Connecting to an External Controller, Cabinet Assembly Spare Parts List and Exploded Parts Diagram, Heat System Spare Parts List and Exploded Parts Diagrams, Water System Spare Parts List and Exploded Parts Diagrams, Electrical System Spare Parts List and Exploded Parts Diagrams, Jandy JXi 400 Installation And Operation Manual (56 pages), Auxiliary Components, Chlorinators, Ozone Generators and Sanitizing Chemicals, Install Pressure Relief Valve Kit #R0336102, 11.3 Cabinet Assembly Spare Parts List and Exploded Parts Diagram. Jandy Pool Heater Wont Ignite [9 Easy Fixes]. Our pool is a little over a month old and we have not been able to use the heater yet. Any new postings here are unlikely to be seen or responded to by other members. JavaScript is disabled. No other "low-hanging fruit" you guys can think of? There's a round hole that you can put a pencil in the hole to release the latch then swing it out to latch it out about 90 degrees. The heater has been giving me a bunch of trouble lately and I was hoping someone here may have some insight. Brand: Zodiac Pool Systems REVIEWS Q&A Powered by TurnTo Review More Purchases | My Posts There are no reviews for this item. Hello , This is an inactive thread. Turned it back on. Faulty Flame Sensor 3. Your link has been automatically embedded. The best method is to remove the air from the gas line. You've already tried the very simplest stuff so here's what I'd do next: The sight glass is glowing. blower comes on, ignitor glows then blower goes off and ignitor turns off. It could be something silly like a stick or acorn is stuck in it's intake. All Activity; Home ; Inground, Fiberglass and Aboveground Swimming Pools ; All Swimming Pools Types ; Jandy Heater - Check IGN Steps @ 82-85 degrees Performance & security by Cloudflare. Little over 4 years old. Same error. This cycle repeats 3 times then I get the above error. Next stupid question: How do I see the ignitor? One last question, have you had a lightning strike or one close by lately? Make a note of where the wires join the valve so you can reconnect them later. Still havent had a plumber come. Get the leads and connect one on each terminal once youve located the terminals. Malfunctioning Of The Valves FAQ: What does the FLO error code mean on the pool heater? We are a registered 501(c)3 non-profit that is funded by user donations. Home Jandy JXi/LXi Ignition Control Kit | R0456900 Ignition Control For Use With: Model 200, 260, 400 JXi and LXi Low NOx Heaters; Natural & Propane Gas. You can call Jandy customer care Monday through Friday, 8 AM-5 PM (PST) on this number- 800.822.7933 or send an email to the following address- productsupport@fluidra.com. Since they put the heater and pool filter main on same circuit I can't run the entire thing now. Jandy lxi not heating, getting ignition fault, help. I took off the top grate and checked for debris. Heaterfixlab.com is a participant in Google Adsense and Ezoic Ad Network. You must log in or register to reply here. Make sure that the vents are not placed beneath decks, stairways, or automobile ports. Do you get a puff of heat from it before it shuts off? I have an LXi, not an LX. We had this issue with our Jandy heater. It's well worth a call out charge to have a qualified gas plumber check flow and pressure for you. Firstly, check that the gas supply installed matches the gas type of the Jandy heater. This error means something in the safety circuit is in a "not safe" mode or as Pool mentioned above it got to the end and there was no ignition source so it shut down. ivereplaced the presssure switch, blower pressure switch, ignition control unit, gas valve and flame sensor. While doing so I disconnected the unit to make examining the heat exchange easier. That includes making sure you were sold the right heater (Gas? There is no loud click when the igniter is powered. Clear editor. When the gas valve opens, you can smell the methyl mercaptan so I know there is gas getting in to the combustion chamber. My heater is giving me a code after about one minute of heating up. Youll notice a side with different terminals when you turn the pressure switch around. pedanticus ILL LET YOU KNOW HOW I MAKE OUT. It could be the cause of your water heaters inability to stay lit. Hi all!We have a Jandy LXi 250 heater for our salt water pool. For one (1) year from the date of retail purchase, Zodiac Pool Systems LLC (Zodiac) warrants all Jandy branded pool heaters to be free of manufactured defects in materials and workmanship. From Google, I was able to figure out that this is indeed an Air Pressure switch (made by Honeywell): http://www.northamericahvac.com/servlet/the-5245/Honeywell-Air-Pressure-Switch/Detail. I tried to fire it up last weekend and it Ask an Expert Home Improvement Questions Pool And Spa Repair Question Summary Answer Summary Gaztech1 here, just signed in, 9H00 am eastern time in CANADA.good morning..I am ready to assist you with your issue. read more. There is that possibility because of how it is made. I have a voltmeter but no clue where to begin testing. The possible causes include- fluctuating filter pump pressure, faulty flame sensor, bad pressure sensor, damaged fan/switch tubing, fan not operating or running slowly, restricted airflow, low gas supply pressure, malfunctioning gas valve, and air in the gas line. It will run up from 65-80's with no problem then throws the error consistently at that point. I do realize I could unplug it and check voltage from the board harness itself, yes, that would be a lot easier, but I'm still afraid of 120vAC right now and won't push my luck unless I have no other choice. Any ideas where is goes of the part number? I removed the front panel and I see the wiring and boards in there. In case the noted reading is not within this range, the gas valve is faulty. Another trick I tried in my dryer repair days was to blow hard on the burner after you hear the gas valve click. It is being practiced by thousands of pool owners just like you. A bad pressure sensor may be why your Jandy Lite2 pool heater wont turn on even when the pump and filter are fine. Jandy tech came out and the heater fired up. It's not super expensive but we see a lot replaced that are good. For a better experience, please enable JavaScript in your browser before proceeding. I can shut off power and have at it, just dont know where to start. This issue can be a result of air leaks, low water levels, stuck skimmer weirs, or clogged suction pipes. Connect each tester probe on the multimeter to each of the gas valves terminals. Greetings to all, I have a brand-spanking-new Jandy Zodiac LXi 400,000 BTU/HR heater that has never worked. So I'm not going to play with that one just yet. If there are no terminals visible, you may need to remove the cover first.

Strong Magnets Screwfix, Oceanhorn 2 Grand Core Break Room, Nerdwallet Summer Internship, Articles J